Tap water · CA

Los Angeles Department of Water and Power

EPA system ID CA1910067 · serves about 3,875,566 people. Every US utility must publish an annual water quality report — here’s the official one (2025), and below it, our plain-English translation.

Read the official report →

What Los Angeles Department of Water and Power found in 2025

39 detected analytes from the utility’s own annual report, hand-normalized — nothing was near or over a federal health-based limit.

DetectedLevelLimit% of limitStatus
Total Coliform Bacteria3.4 % Positives5 % Positives68%Within limit
Specific Conductance873 µS/cm at 25°C1,600 µS/cm at 25°C55%Within limit
Total Dissolved Solids (TDS)545 mg/L1,000 mg/L55%Within limit
Chlorine Residual, Total1.7 mg/L4 mg/L43%Within limit
Total Trihalomethanes (TTHM)33.8 µg/L80 µg/L42%Within limit
Bromate (b)4.1 µg/L10 µg/L41%Within limit
Copper (at-the-tap) AL = 1300 (e)529 µg/L1,300 µg/L41%Within limit
Fluoride0.8 mg/L2 mg/L40%Within limit
Sulfate (as SO4)182 mg/L500 mg/L36%Within limit
Gross Alpha Particle Activity (c)5 pCi/L15 pCi/L33%Within limit
Arsenic3.3 µg/L10 µg/L33%Within limit
Haloacetic Acids (Five) (HAA5)13.4 µg/L60 µg/L22%Within limit
Color, Apparent (unfiltered)3 ACU15 ACU20%Within limit
Chloride92 mg/L500 mg/L18%Within limit
Uranium (c)3.4 pCi/L20 pCi/L17%Within limit
Barium130 µg/L1,000 µg/L13%Within limit
Bromate (b) (uncovered reservoirs)1.3 µg/L10 µg/L13%Within limit
Aluminum96 µg/L1,000 µg/L10%Within limit
Gross Beta Particle Activity (c)4.2 pCi/L50 pCi/L8%Within limit
Turbidity (highest)0.2 NTU5 NTU4%Within limit
Chromium (Hexavalent)0.1 µg/L10 µg/L1%Within limit
Boron NL = 1000360 µg/LNo federal limit
Hardness, Total236 mg/LNo federal limit
Bicarbonate Alkalinity (as HCO3)128 mg/LNo federal limit
Alkalinity, Total110 mg/LNo federal limit
Sodium89 mg/LNo federal limit
Lithium — 2023 monitoring88 µg/LNo federal limit
Lithium80 µg/LNo federal limit
Calcium56 mg/LNo federal limit
Chlorate NL = 80032 µg/LNo federal limit
Magnesium22 mg/LNo federal limit
Temperature18 ºCNo federal limit
Silica (as SiO2)15 mg/LNo federal limit
pH8.3 UnitNo federal limit
Potassium4.4 mg/LNo federal limit
N-Nitrosodimethyhlamine (NDMA) NL=102.1 ng/LNo federal limit
Ammonia + Chloramines (as N)0.5 mg/LNo federal limit
Bromide0.05 mg/LNo federal limit
Phosphate, Ortho (as PO4)0.03 mg/LNo federal limit

Levels and limits are as printed in the utility’s report (“limit” is the EPA MCL, action level, residual limit, or secondary guideline that applies to that row; “ND” = not detected). Utilities publish these reports annually — we re-check every covered utility each July, after the federal publication deadline. Detected doesn’t mean dangerous — most detections sit far below their limits. This is education, not medical advice.

Your tap, if it were a bottle

How Los Angeles Department of Water and Power water stacks up against the bottled aisle

Same minerals, same units — the tap values below come from the utility’s report, placed next to the closest match in our bottled-water database.

MineralYour tapClosest bottled match
Total dissolved solids545 mg/LPerrier at 468 mg/L
Calcium56 mg/LBuxton at 55 mg/L
Magnesium22 mg/LFerrarelle at 23 mg/L
Sodium89 mg/LMattoni at 69.9 mg/L
Sulfate182 mg/LTopo Chico at 180 mg/L
Chloride92 mg/LUliveto at 76 mg/L
Potassium4.4 mg/LCrazy Water at 4.7 mg/L

Tap values are the headline levels from the utility’s annual report (often a highest or average figure); bottled values are label- or report-derived. A closest match is a numeric comparison, not an equivalence or an endorsement.

Zip codes covered

90003 · 90004 · 90005 · 90006 · 90007 · 90010 · 90011 · 90012 · 90013 · 90014 · 90015 · 90016 · 90017 · 90018 · 90019 · 90020 · 90021 · 90024 · 90025 · 90026 · 90027 · 90028 · 90029 · 90031 · 90032 · 90033 · 90034 · 90035 · 90036 · 90037 · 90038 · 90039 · 90041 · 90042 · 90045 · 90049 · 90057 · 90062 · 90064 · 90065 · 90067 · 90068 · 90071 · 90077 · 90089 · 90094 · 90095

Boundary zips partially served by other systems are deliberately unlisted — check your exact zip.